ISSN 2326-7275
Research Article
Variation of musculocutaneous nerve in arm with additional muscular slip in forearm
International Journal of Anatomy and Physiology ISSN: 2326-7275 Vol. 2 (3), pp. 020-022, March, 2013. © International Scholars Journals
Full length research paper
Variation of musculocutaneous nerve in arm with additional muscular slip in forearm
Shweta J.Patel1, Rashvaita k. Patel2, Chintan Bhatt3 and C.D. Mehta4
1,2,3,4Department of Anatomy, government medical college, Surat, India.
Accepted 14 March, 2013
Abstract
The Musculocutaneous nerve arises from the lateral cord of the brachial plexus, passes inferolaterally and then pierces through the coracobrachialis, after supplying it descends between the biceps and the brachialis, sending branches to both and continues as the lateral cutaneous nerve of the forearm. Variations in the origin, course, branching pattern, termination and the connections of the musculocutaneous nerve are not uncommon. These variations have clinical significance during surgical procedures, in the brachial plexus block and in diagnostic clinical neurophysiology. A detailed study was carried out on 80 upper limbs by using 40 embalmed cadavers during 4 years in anatomy department during routine undergraduates’ dissection classes. Dissection of the infraclavicular part of the brachial plexus was done. The variations in the origin, number and course, and their correlations to the coracobrachialis were noted. Absence of the musculocutaneous nerve was noted in 2 upper limbs (2.5 %).The musculocuatenous nerve was found but not piercing the coracobrachialis in 1 upper limb. (1.25%) and the nerve was found to rejoin the median nerve. The observations show that the musculocutaneous nerve has significant variations and that these variations have clinical significance in post traumatic evaluations and in the exploratory innervations of the arm for peripheral nerve repair. It is important for surgeons, clinicians and anatomist to be aware of possible anatomical variations to avoid unexpected complications.
Key words: Musculocutaneous nerve, brachial plexus, median nerve, coracobrachialis, biceps brachii.
Patel SJ, Patel RK, Bhatt C and Mehta CD
Research Article
Morphological study of cutaneous ligaments
International Journal of Anatomy and Physiology ISSN: 2326-7275 Vol. 2 (3), pp. 011-013, March, 2013. © International Scholars Journals
Full length research paper
Morphological study of cutaneous ligaments
Anjali S. Sabnis
K.J. Somaiya Medical College and Hospital, Sion, Mumbai -400022, Maharashtra, India.
*Corresponding author. Email: dranjus2003@yahoo.com
Accepted 04 February, 2013
Abtract
The cutaneous ligaments of phalanges of palm and foot are fine and sender fibrous strips running from tendon sheath to skin over phalanges. Different opinions regarding cutaneous ligaments have created interest to find out the structure of them. By keeping aim in the mind to study ligaments in relation to attachment, thickness, length and histological structure, a study was conducted on 80 digits of 8 cadavers. These ligaments are running in relation to ventral and dorsal aspect of the digital nerve from tendon sheath to the skin. Attachment of the ligaments to the skin is suggestive of stabilization of skin during movements. The morphological data of cutaneous ligaments will be helpful in surgical implication of Duputren’s Contracture, replantation and revascularization of the digit. Thus clinical significance of cutaneous ligaments has attracted vascular surgeons in microsurgery of hand.
Key words: Cutaneous ligaments, Cleland’s ligament, Grayson’s ligaments, Duputren’s contracture.
Sabnis AS
Research Article
Anatomical study of the human ansa cervicalis nerve and its variations
International Journal of Anatomy and Physiology Vol. 2 (1), pp. 014-019, March, 2013. © International Scholars Journals
Full length research paper
Anatomical study of the human ansa cervicalis nerve and its variations
Ahmed M.S. Hegazy
Anatomy and Embryology, Department of Anatomy, Faculty of Medicine, Benha University, Egypt. E-Mail: Ahmed0562301954@yahoo.com
Accepted 27 February, 2013
Abstract
With the expanding use of the ansa cervicalis nerve for laryngeal reinnervation procedures. So the aim of this work was to study the anatomical variations of ansa cervicalis in its roots, course and branching pattern. Twenty five Egyptian necks (50 sides) were dissected. The results showed that the ansa cervicalis (AC) consisted of two roots: superior and inferior roots. These two roots joined together to form a nerve loop. The superior root of AC originated from the hypoglossal nerve in 100%.The superior root of AC descended in front of the external carotid artery in 68% and in front of the internal carotid artery in 32%. The inferior root of AC was derived from the ventral rami of C2 and C3 in 84% and from C2 in 16%. There were four morphological forms of the loop of ansa cervicalis: I- U-shaped loop in 84%. II- Y-shaped loop in 8%. III- double fused Y-shaped loop in 4%.VI- double separate Y-shaped loop in 4%. The superior root of AC gave a branch to the superior belly of omohyoid in 96% and a branch to sternomastoid in 24% . The inferior root of AC gave a branch to inferior belly of omohyoid and a communicating branch to phrenic nerve in 4%. These anatomical variations of the ansa cervicalis can be used in surgical procedures such as reinnervation of the laryngeal muscles following the damage of recurrent laryngeal nerve and to avoid the iatrogenic injuries of this nerve during the surgical operations of the neck.
Key words: Ansa cervicalis, human, anatomical variations, surgical procedures,
Hegazy AMS
Case Report
Transmaxilar access for treatment of blow-out orbital fracture with titanium mesh
International Journal of Anatomy and Physiology Vol. 1 (1), pp. 006-010, December, 2012. © International Scholars Journals
Full Length Research Paper
Transmaxilar access for treatment of blow-out orbital fracture with titanium mesh
Edson Martins de Oliveira Junior1*, Fernando Elias Melhem1,2, Antonio Carlos Campos1,b, Marcia Maria de Gouveia1, and Carlos Augusto Alves Ferreira1
1Department of Dentistry - Hospital Universitário - Universidade de São Paulo, São Paulo/SP - Brazil.
2Department of Surgery - Prosthesis and Maxillofacial Trauma - Faculdade de Odontologia - Universidade de São Paulo, São Paulo/SP - Brazil.
*Corresponding author. E-mail: jr.odonto@gmail.com
Received 04 September, 2012; Accepted 23 December, 2012
Abstract
Orbital fractures blow-out type result from traumatic force applied directly to the eye, often associated fracture of the medial orbital wall, without involvement of adjacent bones. This type of fracture results in prolapse of the orbital contents into the maxillary and/or ethmoid sinus. Diplopia, enophthalmos, hiposfagma, periorbital edema and ecchymosis are the major clinical findings. The Computerized Tomography (CT) scan of the orbits is the gold standard in accurate diagnosis of these fractures in order to determine the degree of prolapse orbital structuresinto thesinus, oriented their treatment. About the surgical access to these fractures is classically done by extra-oral way, through subciliar and transconjunctivalaccesses, which sometimes result in undesirable local complications such as scar, ectropion or entropion. This paper aims to report a case of blow-out fracture for which we chose to access via the maxillary sinus, by Caldwell-Luc access, with reduction of the fracture and deserniation of orbital content through titanium mesh fixed on the superior and medial walls of the maxillary sinus.
Key words: Orbital, trauma, fracture, maxillary sinus, titanium mesh.
Edson Martins JOD, and Ferreira CAAF, Campos AC, Melhem FE, Gouveia MMD
Research Article
Effect of hypochlorite sodium as an agent detergent on mortality response of fishes
Journal of Anatomy and Physiology Vol. 1 (1), pp. 001-005, December, 2012. © International Scholars Journals
Full Length Research Paper
Effect of hypochlorite sodium as an agent detergent on mortality response of fishes
Abdolreza Jahanbakhshi*, Aliakbar Hedayati and Fatemeh Ghaderi Ramazi
Department of Fishery, Faculty of Fisheries and Environment, Gorgan University of Agricultural Science and Natural Resources, Gorgan, Iran.
*Corresponding author. E-mail: abdolreza.jahanbakhshi@yahoo.com
Received 04 September, 2012; Accepted 05 December, 2012
Abstract
The acute toxicity of hypochlorite sodium to four species of freshwater fishes was investigated in laboratory tests. All fishes were exposed to hypochlorite sodium at several selected concentrations and number of mortality was registered after 24, 48, 72 and 96 h. LC50 values were determined with probite analysis. According to the results LC50 96 h hypochlorite sodium were 42.9 ± 0.20, 33.2 ± 0.36, 22.7 ± 0.22, 41.7 ± 0.19 for common carp, silver carp, roach and gold fish respectively. According to the results procure in the present experiment; hypochlorite sodium had more toxicity to roach compared to silver carp, common carp and gold fish.
Key words: Hypochlorite sodium, mortality, acute toxicity, freshwater, LC50.
Hedayati A and Ramazi FG, Jahanbakhshi A